Power Connection Specifications

  1. Low Voltage Safety: Illuminated letters operate on DC 12V or 24V low voltage; connecting to AC 110V–240V is strictly prohibited.
  2. Polarity Identification: Different colored wires represent different polarities; ensure wires of the same polarity are connected together.
  3. Transformer Connection: Connect the gathered letter wires to the low-voltage output terminal of the transformer (note the + / – poles).
  4. Insulation: Connections should be soldered or tightly twisted and must be wrapped with insulating tape.
  5. Main Power Input: Connect the (L and N) terminals of the transformer to the local mains (AC 110V–240V).

Installation Steps

  1. Positioning: Apply the 1:1 installation template to the target wall surface.
  2. Drilling: Drill holes at the marked points on the template for mounting screws and wiring.
  3. Fixing: Screw the studs into the back of the letters, align them with the holes, and secure with nuts or adhesive on the back if necessary.
  4. Wiring Loop: If the sign length exceeds 3 meters, connect both ends of the main busbar to the transformer to prevent voltage drop.

Equipment Daily Maintenance and
Troubleshooting Guide


ProblemInspection ItemsSolutions
No Illumination1. Check whether the transformer indicator light is on. 2. Check whether the wiring is correct.1. Check whether the circuit is disconnected. 2. Replace or adjust the transformer output cable.
Partial LightingThe polarity of the letters connected to the main power line is reversed.Adjust the wiring of the letters that are not lighting up.
FlickeringCheck whether the letter wiring is short-circuited.1. Reconnect the short-circuited wires correctly. 2. Check whether the transformer is overloaded.
Item Maintenance Content Frequency
Cleaning Wipe with a soft dry cloth or neutral cleaner. Strong acids and alkalis are strictly prohibited.Quarterly
Wiring Check Check if transformer connections are loose, aging, or overheating.Bi-annually
Waterproofing Check if the silicone sealant is cracked to ensure outdoor waterproof performance.Annually
Fastening Check if screws or structural adhesive are loose due to environmental factors.Annually

Troubleshooting

  • No Lighting: Check if the transformer indicator is on, or swap the polarity of the output wires.
  • Partial Lighting: Check if the polarity of the non-illuminated letters is reversed.
  • Flickering: Check for short circuits or if the transformer is overloaded.

CRITICAL WARNING: NEVER connect the signage directly to the high-voltage main power!